Veterinary X‑Ray Equipment and Light Signals: Keeping Imaging Environments Controlled and Safe

Explaining Vet X‑Ray Safety Lights



Veterinary X‑ray warning lights are control area signals placed at entry points to X‑ray rooms. These lights switch on whenever the generator is in use, indicating that the area is subject to controlled radiation exposure.



The Importance of Fail‑To‑Safe Systems in Veterinary Radiography


Fail‑to‑safe designs ensure if a warning light or system malfunctions, the X‑ray generator will be disabled. This eliminates the risk of accidental exposure, safeguarding both humans and animals.



The Use of Two‑Stage Warning Lights


Two‑stage warning lights provide a clearer distinction between room status. The first light (usually amber) shows the room is restricted, and the second (red) signals active X‑ray use with phrases like “DO NOT ENTER”.



Veterinary X‑Ray Systems: Choosing What Suits Your Practice



Portable Imaging Solutions


Portable models like the VET‑20 are designed for field and clinical use. Features include laser positioning, remote exposure, LCD screen, and a tough exterior — ideal for ambulatory work or small-animal clinics.



Cubex Systems for Lightweight Precision


Weighing approximately 13 kg, the Cubex range includes features such as digital displays, dual laser pointers, and easy pairing with digital imaging platforms. These systems offer portability and performance.



Fixed X‑Ray Units for Larger Clinics


Integrated X-ray systems like the ZooMax are suited for in-house use. Larger or mixed-animal practices may choose ceiling-mounted, telescopic systems to increase workflow effectively.



Understanding Legal Safety Requirements



Veterinary radiography must meet the standards of the Ionising Radiations Regulations 2017 (IRR17). Clinics are expected to provide:




  • Warning lights at every access point that operate automatically and follow fail‑to‑safe design principles.

  • Clearly labelled isolation switches located outside the radiation zone.

  • Up-to-date radiation risk assessments, local rules, and guidance under the responsibility of a Radiation Protection Supervisor (RPS).



Best Practice Recommendations




  • Choosing the right lights: Opt for LED fail‑to‑safe lights visible from a distance and compliant with IRR17. Two‑stage lights are recommended for added clarity.

  • System selection: Choose portable systems like VET‑20 or Cubex for versatility. Integrated setups may better serve high-volume or equine practices.

  • Installation and documentation: Collaborate with your RPS or safety advisor to install correctly, and ensure all testing and documentation meet regulatory standards.



Answers to Common Veterinary Radiography Queries



What does “fail‑to‑safe” mean?

If the safety light fails, the x-ray unit disables itself automatically.



Are two-stage lights legally required?

Not mandatory, though they offer enhanced communication.



Can I use a portable X‑ray machine in both the clinic and the field?

Yes, both VET‑20 and Cubex models are adaptable to mobile and fixed settings.



What is the weight of portable X‑ray units?

The VET‑20 weighs about 9.8 kg and the Cubex around 13 kg. Both are lightweight enough for daily use.



Do I need approval to install warning lights?

Yes, installations must follow IRR17 standards and be verified by your RPS or an authorised adviser. Proper planning and records are essential.



A Note on Choosing the Right Solutions



Combining compliant warning lights with the right x-ray system is central to more info safe veterinary imaging. Whether you're mobile, in a small clinic or managing a busy equine service, investing in reliable solutions ensures safety and image quality. Visit xray4vets to find radiography products that match your practice’s needs.